Thermocouple & RTD Combination

 

Standard Specifications for RTD/Thermocouple Combo:

  • Platinum 100 ohm +/- 0.12 % @ 0 C (Class B Element)
  • Temperature Coefficient= .00385
  • 2-Wire Configuration: 24 AWG, solid nickel wire, with fiberglass insluation
  • Type K Thermocouple
  • Special limits of accuracy, +/- 1.1 C or +/- 0.40%
  • 2-Wire Configuration: 24 AWG solid thermocouple wire, fiberglass insulation
  • Ungrounded Junction
  • Temperature range: -50 to 600 C
  • Stainless steel sheath: 0.188" O.D, Each probe etched is etched with a lot number to provide traceability.
  •  

    Changes can be made to:

  • The RTD type:   PT25, PT200, PT500, PT1000, PT2000
  • Nickel, Copper, Balco, Thermistor, or Semi-Conductor Temperature Elements
  • Thermocouple type: T, J, E, N, R, S, B, W5
  • Temperature Range: (-250 to +850 C)
  • Wire Configuration
  • Sheath Diameter
  • Sheath Length
  • Wire Material
  • Lead Length
  • Fittings

     

     

  • Live chat by BoldChat
    Live TemperatureSensor Support