Thermocouple & RTD Combination
Standard Specifications for RTD/Thermocouple Combo:
Platinum 100 ohm +/- 0.12 % @ 0 C (Class B Element)
Temperature Coefficient= .00385
2-Wire Configuration: 24 AWG, solid nickel wire, with fiberglass insluation
Type K Thermocouple
Special limits of accuracy, +/- 1.1 C or +/- 0.40%
2-Wire Configuration: 24 AWG solid thermocouple wire, fiberglass insulation
Ungrounded Junction
Temperature range: -50 to 600 C
Stainless steel sheath: 0.188" O.D, Each probe etched is etched with a lot number to provide traceability.
Changes can be made to:
The RTD type: PT25, PT200, PT500, PT1000, PT2000
Nickel, Copper, Balco, Thermistor, or Semi-Conductor Temperature Elements
Thermocouple type: T, J, E, N, R, S, B, W5
Temperature Range: (-250 to +850 C)
Wire Configuration
Sheath Diameter
Sheath Length
Wire Material
Lead Length
Fittings
sales@thermometricscorp.com